수면정신생리

수면정신생리 (6권2호 110-115)

Effect of Mandibular Repositioning Device on Airway Size and Airway Collapsibility in Obstructive Sleep Apnea Syndrome : Cine CT during Sleep

수면무호흡증 환자에서 Mandibular Repositioning Device가 Airway size와 Airway Collapsibility에 미치는 효과

Hong, Seung-Bong;Kyung, Seung-Hyun;Han, Hyun-Jung;Na, Dong-Kyu;Son, Young-Ik;Park, Young-Chel;

Department of Neurology, Samsung Medical Center, Sungkyunkwan University School of Medicine;Department of Orthodontics, Institute of Oral Health, Samsung Medical Center, Sungkyunkwan University School of Medicine;Department of Neurology, Anyang General Hospital;Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine;Department of Otorhinolaryngology, Samsung Medical Center, Sungkyunkwan University School of Medicine;Department of Orthodontics, College of Dentistry, Yonsei University;

Abstract

Objectives: To investigate the effect of mandibular repasitioning device on airway sige and airway collapsibility in patients with obstructive sleep apnea syndrome(OSAS). Methods: Cine CT with polysomnographic monitoring was performed during sleep in nine(OSAS) patients before and after manibular repositioning device(MRD) application. Axial CT images were obtained in five upper airway levels(retropalatal-high, retroalatal-low, retroglossal, epiglottis, and hypopharynx levels). In each airway level, one axial CT image was obtained during sleep apnea period and 10 serial axial CT images were scanned every 1 second during normal sleep breathing. After wearing MRD, all CT images were obtained by the same method. The cross-sectional areas of airway were measured by automatic tracing method. The changes of minimum airway size and maximum airway size after MRD were evaluated. The airway collapsibility was calculaed before and after MRD. Results: During sleep apnea, the airway of retropalatal-low level was the most frequently narrowest site. During normal sleep breahing the minimum airway size was increased significantly after MRD at retropalatal-low level(p=0.011). The mean airway collapsibility was the highest at retropalatal-low level. MRD decreased the airway collapsibility significantly at retropalatal-low level(p=0.021) and epiglottis level(p=0.038). Conclusions: The enlargement of the minimum airway size and decreased airway collapsibility may be the therapeutic mechanism of MRD in obstructive sleep apnea.

Keywords

Obstructive sleep apnea syndrome;Mandibular repositioning device;Cine CT;Airway size;Airway collapsibility;